Posteriorly Dislocated Capsular Tension Ring Removed Using the Chandelier Illumination System PDF Print E-mail
Written by Amar Agarwal, Soosan Jacob, Mandeep Lamba, Athiya Agarwal, Sunita Agarwal.   
Amar Agarwal, M.S.; F.R.C.S.; F.R.C.Ophth
Soosan Jacob, MS, DNB, FRCS, MNAMS
Mandeep Lamba, MBBS, FERC
Athiya Agarwal, M.D.;D.O.
Sunita Agarwal, M.S.;D.O.

Posteriorly Dislocated Capsular Tension Ring Removed Using the Chandelier Illumination System

Volume 34, Number # 2, 2006 Series

Amar Agarwal, M.S.; F.R.C.S.; F.R.C.Ophth
Soosan Jacob, MS, DNB, FRCS, MNAMS
Mandeep Lamba, MBBS, FERC
Athiya Agarwal, M.D.;D.O.
Sunita Agarwal, M.S.;D.O.


1. Lang Y, Fineberg E , Garzozi HJ. Vitrectomy to remove posteriorly dislocated endocapsular ring. J Cataract Refract Surg.; 2001 ,Nov;27(11): 1710 �11.

2. Bhattacharjee H, Bhattacharjee K. Management of a posteriorly dislocated endocapsular tension ring and a foldable acrylic intraocular lens. J Cataract Refract Surg. 2004 Jan;30(1):243-6.

3. Levy J, Klemperer I. Posteriorly dislocated capsular tension ring. Ophthalmic Surg Lasers Imaging. 2005 Sep-Oct;36(5):416-8.

4. Ahmed II, Chen SH. Surgical repositioning of dislocated capsular tension rings. Ophthalmol. 2005 Oct;112(10):1725-33.

5. Moreno-Montanes J, Heras H, Surgical treatment of a dislocated intraocular lens-capsular bag-capsular tension ring complex. J Cataract Refract Surg. 2005;31(2):270-3.

6. Hara T, Hara T, Yamada Y. �Equator ring� for maintenance of the completely circular contour of the capsular bag equator after cataract removal. Ophthalmic Surg. 1991;22:358�359.

7. Cionni RJ, Osher RH. Management of profound zonular dialysis or weakness with a new endocapsular ring designed for scleral fixation. J Cataract Refract Surg. 1998 Oct;24(10):1299-306.

8. Menapace R.J., Findl O., Georgopoulos M., et al. The capsular tension ring: designs, applications, and techniques Cataract Refract Surg 2000; 26:898�912

9. Jacob S, Agarwal A, Agarwal A, et al . Trypan blue as an adjuvant for safe phacoemusification in eyes with white cataract. J Cataract Refract Surg. 2002 ;28(10):1819�25.

10. Jacob S, Agarwal A, Agarwal A. Efficacy of a capsular tension ring for phacoemulsification in eyes with zonular dialysis. J Cataract Refract Surg. 2003;29(2):315-21.

11. Little BC, Richardson T, Morris S. Removal of a capsular tension ring from the anterior chamber angle. J Cataract Refract Surg. 2004;30(9), 1832-34.

12. Vander JF, Eagle RC Jr, Brown GC. Retinal tolerance of an implantable light source for use during vitrectomy surgery. Ophthalmic Surg. 1991 Dec;22(12):735-9.

13. Natarajan S, Dongargaonkar S. Wide angle viewing systems in vitreous surgery. Garg A, Pandey. Advances in Ophthalmology ; Jaypee Brothers ; First Edition 2003.
14. Kaiser R. Vitrectomy; When and how size matters. Review of Ophthalmology. VOL :12:12, Dec2005.

15. Packo K. Early experience reveals benefits of 25 G vitrectomy. Review of Ophthalmology , Vol 11:08, Issue, Aug � 2004.

 

Related Websites | http://www.elibraryweb.net | http://issues.elibraryweb.net


2009 - 2012 Jaypee Highlights Medical Publishers, Inc. All rights reserved - email: cservice@jphmedical.com
TEL: From U.S.A 011-507-301-0496, Out U.S.A 00-507-301-0496 ~ FAX: From U.S.A 011-507-301-0499, Out U.S.A 00-507-301-0499
P. O. Box 0818-00848, Panama, Republic of Panama